Description
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.
CVSS Metrics
- Vector
- CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Attack Vector
- network
- Complexity
- low
- Privileges
- none
- User Action
- none
- Confidentiality
- undefined
- Integrity
- undefined
- Availability
- undefined
- Weaknesses
- CWE-1391
Metadata
- Primary Vendor
- UNKNOWN
- Published
- 1/26/2026
- Last Modified
- 1/26/2026
- Source
- NIST NVD
- Note: Verify all details with official vendor sources before applying patches.
Affected Products
No affected products information available.